You watched
Refrigerant-euro Refrigerant supplier for modern Industries
Catalog
Client
Language:
Currency:
Theme:
+48 520 917 268
Our location:
Svätovavrinecká 13920/10, 831 01 Bratislava
Phones:
Working hours
  • Mon-Fri: from 9 am to 6 pm
  • Sat: from 10 am to 5 pm
  • Sun: from 11 am to 4 pm
E-mail
We are on social networks
Go to contacts
0 0
Catalog
Home
Viewed
1
Wishlist
0
Compare
0
Contacts

R410A Refrigerant 10 kg Cylinder

Product Code: R410a Refrigerant 10 kg
0
All about product
Description
Reviews 0
Recommended
In Stock
380.00€
Found cheaper?
Delivery
By courier around the city
By courier around the city
DHL
DHL
UPS
UPS
Payment
payment on account payment on account
In cash In cash
Customer support
Customer support service
24/7 without days off
R410A Refrigerant 10 kg Cylinder
380.00€
Description

R410A Refrigerant 10 kg — HFC Refrigerant Blend for Air Conditioning and Cooling Systems

R410A refrigerant 10 kg is a high-pressure HFC refrigerant blend consisting of R32 and R125. It is intended for air conditioning, heat pump and refrigeration equipment specifically designed or approved for the use of R410A.

R410A is widely used in air conditioning systems, heat pumps, commercial cooling equipment and selected refrigeration applications.

R410A has zero ozone depletion potential (ODP = 0). However, it is a fluorinated greenhouse gas with a relatively high global warming potential.

Important: R410A should only be used in equipment designed or approved for this refrigerant. Always follow the equipment manufacturer's technical documentation when selecting, charging and servicing the system.

R410A Technical Specifications

Refrigerant designation R410A
Refrigerant type HFC blend
ASHRAE designation R410A
Composition R32 / R125 — 50% / 50% by mass
Chemical components Difluoromethane (R32) and pentafluoroethane (R125)
Safety classification A1
Ozone Depletion Potential (ODP) 0
GWP100 2,088*
Temperature glide Very low, approximately 0.1 K
Normal boiling point Approximately −51 °C
Cylinder filling 10 kg
Net refrigerant weight 10 kg
Cylinder type According to the specification of the supplied product
Gross weight Depends on cylinder type
Manufacturer According to product documentation
Country of origin According to product documentation
Batch / Lot According to product marking and documentation

* GWP100 of 2,088 is the commonly referenced IPCC AR4 value for R410A. The applicable regulatory methodology and the supplied product documentation should be used for regulatory calculations.

Technical Documentation for R410A

The Safety Data Sheet (SDS/MSDS) provides information about refrigerant safety, handling, storage and protective measures.

The Certificate of Analysis (COA) may relate to a specific production batch. Product composition, purity and batch-specific technical characteristics should be verified against the documentation supplied with the actual refrigerant.

Key Characteristics of R410A

R410A is a zeotropic HFC blend with very low temperature glide, consisting of equal mass proportions of R32 and R125.

R410A operates at relatively high pressures compared with several older refrigerants. Therefore, equipment, service tools, components and procedures must be suitable for R410A operating conditions.

R410A has an A1 safety classification under the applicable refrigerant safety classification system.

Actual operating pressure, evaporation and condensing temperatures, refrigerant charge quantity and system performance depend on the design of the equipment and its operating conditions.

Charging R410A

R410A should be charged using the procedure specified by the equipment manufacturer and with service equipment rated for the pressure and refrigerant being used.

Because R410A is a refrigerant blend, charging procedures should be performed according to the manufacturer's instructions to maintain the intended refrigerant composition.

Applications of R410A

R410A is used in equipment specifically designed or approved for this refrigerant.

Typical applications include:

  • Residential and commercial air conditioning systems
  • Heat pump systems designed for R410A
  • Commercial cooling equipment
  • Selected refrigeration systems
  • HVAC equipment designed for high-pressure HFC refrigerants
  • Chillers and other cooling equipment where R410A is specified
Compatibility notice: R410A should not be used as a direct replacement for another refrigerant unless compatibility has been confirmed. Always follow the equipment manufacturer's specifications and retrofit instructions.

R410A and R22 Equipment

R410A was developed for use in systems designed specifically for R410A and has different operating pressure characteristics from R22.

Although R410A has been widely used in modern air conditioning systems, it should not be treated as a universal drop-in replacement for R22.

R410A operates at substantially different pressures and requires equipment, components and service procedures suitable for R410A.

Important: Do not charge an R22 system with R410A unless the equipment manufacturer specifically approves the conversion and provides the required retrofit procedure.

R410A Environmental and Regulatory Information

Ozone Depletion Potential
ODP: 0
Global Warming Potential
GWP100: 2,088*

R410A has zero ozone depletion potential. However, it has a relatively high global warming potential and is classified as a fluorinated greenhouse gas.

For this reason, R410A should not be described as an "eco-friendly" or "low-GWP" refrigerant.

The use, sale, installation and servicing of equipment containing fluorinated greenhouse gases may be subject to applicable EU F-gas requirements and national regulations.

Before purchasing or using R410A, users and operators should verify the requirements applicable to the specific equipment, application and country.

R410A System Performance

R410A is used in systems where its pressure-temperature characteristics and thermodynamic properties are appropriate for the equipment design.

Actual cooling capacity, energy efficiency, operating pressure and temperature depend on the compressor, heat exchangers, expansion device, ambient conditions and system configuration.

Refrigerant charge quantity should therefore always be determined according to the equipment manufacturer's specifications.

Before Buying R410A Refrigerant 10 kg

Before placing an order, check the following:

  1. Refrigerant designation — confirm that the equipment requires R410A.
  2. Equipment compatibility — verify that the system is designed or approved for R410A.
  3. Required refrigerant charge — check the quantity specified by the equipment manufacturer.
  4. Service equipment — make sure gauges, hoses, recovery equipment and other tools are suitable for R410A operating pressures.
  5. Charging procedure — follow the manufacturer's instructions for charging the refrigerant blend.
  6. Applicable regulations — verify the F-gas and national requirements applicable to the intended use.
  7. Product documentation — review the available Safety Data Sheet (SDS/MSDS) and Certificate of Analysis (COA), and confirm the documentation applicable to the supplied batch.

Buy R410A Refrigerant 10 kg

R410A refrigerant in a 10 kg cylinder is intended for professional air conditioning, heat pump and cooling applications where R410A is specified or approved by the equipment manufacturer.

For wholesale R410A orders and larger-volume supplies, contact us to confirm:

  • Current availability
  • Available packaging options
  • Delivery arrangements
  • Commercial terms
  • Product documentation

For professional applications, always verify equipment compatibility and applicable regulatory requirements before purchase and servicing.

Frequently Asked Questions

What is R410A refrigerant?

R410A is an HFC refrigerant blend consisting of R32 and R125 in a 50/50 mass ratio. It is widely used in air conditioning, heat pump and selected cooling systems designed for R410A.

What is the composition of R410A?

R410A consists of approximately 50% R32 and 50% R125 by mass.

Does R410A have an ozone depletion potential?

No. R410A has an ODP of 0 and does not deplete the ozone layer.

What is the GWP of R410A?

The commonly referenced IPCC AR4 GWP100 value for R410A is 2,088. The applicable regulatory methodology should be used for current regulatory calculations.

Is R410A a low-GWP refrigerant?

No. R410A has a relatively high GWP and should not be described as a low-GWP refrigerant.

Can R410A replace R22?

R410A should not be considered a universal direct replacement for R22. The two refrigerants have different pressure characteristics, and equipment must be specifically designed or approved for R410A.

Is R410A suitable for heat pumps?

Yes. R410A has been widely used in heat pump systems and air conditioning equipment designed for this refrigerant. Always verify the refrigerant specified by the equipment manufacturer.

Can R410A be used in any air conditioning system?

No. R410A should only be used in equipment specifically designed or approved for R410A. Always check the equipment manufacturer's technical documentation before charging.

What safety class is R410A?

R410A has an A1 safety classification under the applicable refrigerant safety classification system.

Need R410A in Larger Quantities?

For wholesale R410A supplies, larger-volume orders and commercial enquiries, contact us to discuss availability, packaging and delivery options.

Reviews

There are no reviews for this product.

There are no reviews for this product, be the first to leave your review.

380.00€