24/7 without days off
R449A Refrigerant 10 kg Cylinder
24/7 without days off
R449A refrigerant 10 kg is a zeotropic HFO/HFC refrigerant blend developed for commercial and industrial refrigeration applications. It is used in refrigeration systems designed for R449A and is commonly associated with applications where R404A or R507A has traditionally been used.
R449A combines HFC and HFO refrigerant components and is classified as A1 under the referenced ASHRAE refrigerant safety classification. The refrigerant has zero ozone depletion potential and a substantially lower GWP than legacy high-GWP refrigerants such as R404A.
R449A 10 kg — Technical Specifications
| Refrigerant designation | R449A |
|---|---|
| Refrigerant type | Zeotropic HFO/HFC blend |
| R32 content | 24.3% by mass |
| R125 content | 24.7% by mass |
| R134a content | 25.7% by mass |
| R1234yf content | 25.3% by mass |
| Safety classification | A1 |
| Ozone Depletion Potential (ODP) | 0 |
| Global Warming Potential (GWP100) | 1,282 according to IPCC AR5 |
| Net refrigerant quantity | 10 kg |
| Physical state | Liquefied gas under pressure |
| Typical lubricant | POE oil, subject to the equipment manufacturer's specification |
| Packaging / cylinder | According to the supplied product specification |
| Manufacturer | According to the actual product documentation |
| Country of origin | According to the actual product documentation |
| Batch information | According to the product label and accompanying documentation |
R449A is a four-component blend. The composition shown above corresponds to the commonly published R449A formulation. Product-specific purity, filling tolerance, packaging, manufacturer, origin and batch information should be confirmed using the actual TDS, SDS and product label.
What Is R449A Refrigerant?
R449A is a zeotropic HFO/HFC refrigerant blend developed for commercial and industrial refrigeration.
It contains R32, R125, R134a, R1234yf. The combination was developed to provide refrigeration performance comparable to legacy refrigerants while significantly reducing GWP compared with R404A and R507A.
R449A is commonly used in commercial refrigeration applications including supermarket refrigeration, condensing units, cold rooms and other systems designed or retrofitted for this refrigerant.
Key Characteristics of R449A
- Zeotropic HFO/HFC refrigerant blend.
- Four refrigerant components: R32, R125, R134a, R1234yf.
- ASHRAE safety classification: A1.
- Ozone Depletion Potential (ODP): 0.
- GWP100: 1,282 using IPCC AR5 values.
- Designed for commercial and industrial refrigeration applications.
- Used as a lower-GWP alternative to R404A and R507A in selected systems.
- Typical lubricant: POE, subject to equipment manufacturer approval.
R449A Compared With R404A
One of the main reasons R449A is used in commercial refrigeration is its substantially lower GWP compared with R404A.
Chemours reports a GWP of 1,282 for R449A using the IPCC AR5 methodology and describes it as a lower-GWP alternative for R404A and R507A applications. This is a technical comparison rather than a statement that R449A is environmentally harmless or suitable for every refrigeration system.
Applications of R449A Refrigerant
R449A is intended for refrigeration systems where its technical characteristics are compatible with the equipment.
- Commercial refrigeration systems
- Supermarket refrigeration
- Cold rooms and refrigerated storage
- Medium-temperature refrigeration
- Low-temperature refrigeration
- Condensing units
- Commercial refrigeration cabinets
- Industrial refrigeration applications
Actual application suitability must be confirmed against the equipment manufacturer's technical documentation.
R449A Refrigerant 10 kg for Professional Use
The 10 kg R449A format is suitable for professional refrigeration installation, servicing and maintenance where R449A is specified or approved.
It can be used by refrigeration contractors, service technicians, commercial refrigeration companies and other professional customers requiring R449A for compatible systems.
R449A Retrofit Applications
R449A was developed as a lower-GWP alternative to refrigerants such as R404A and R507A. It has been used in retrofit applications as well as new refrigeration systems.
However, a retrofit is system-specific. Before replacing an existing refrigerant, the technician should verify compressor compatibility, lubricant requirements, operating pressures, expansion controls, discharge temperature and the manufacturer's retrofit instructions.
- Check whether the compressor manufacturer approves R449A.
- Confirm the required lubricant type and oil condition.
- Verify expansion valve and control requirements.
- Check operating and discharge temperatures.
- Confirm the required refrigerant charge.
- Follow the manufacturer's retrofit procedure.
R449A Charging and Handling
R449A is a blended refrigerant stored as a liquefied gas under pressure. Handling and charging should follow the equipment manufacturer's procedure, the refrigerant manufacturer's technical documentation and the applicable SDS.
- Verify that the system is designed or approved for R449A.
- Use service equipment suitable for the refrigerant.
- Follow the specified charging procedure for the blend.
- Use appropriate personal protective equipment.
- Protect cylinders from excessive heat and physical damage.
- Prevent uncontrolled refrigerant release.
- Recover refrigerant according to applicable requirements.
- Follow the current SDS for storage and emergency procedures.
R449A Environmental and Regulatory Information
R449A contains fluorinated greenhouse gas components and is therefore subject to applicable F-gas requirements.
R449A has an ODP of 0 and a GWP substantially below that of R404A and R507A. Using the IPCC AR5 methodology, Chemours reports a GWP of 1,282 for R449A.
The current European Union framework for fluorinated greenhouse gases is Regulation (EU) 2024/573. Requirements can depend on the equipment, refrigerant charge, application and date, so regulatory compliance should be assessed for the actual installation and intended use.
Therefore, it is preferable to describe R449A using measurable technical characteristics such as its GWP, ODP and safety classification rather than simply calling it an "eco-friendly" refrigerant.
R449A Compatibility
R449A should not automatically be substituted for another refrigerant. Similar application does not by itself guarantee compatibility.
Before using R449A in an existing system, verify:
- Compressor compatibility
- Lubricant compatibility
- Expansion valve requirements
- Operating pressure and temperature
- System charge requirements
- Discharge temperature
- Control settings
- Manufacturer retrofit instructions
- Applicable F-gas requirements
R449A and R448A
R449A and R448A are both HFO/HFC blends used in commercial refrigeration, but they have different compositions and thermodynamic characteristics. They should not be treated as interchangeable solely because they are used in similar applications.
Always verify the refrigerant designation specified by the equipment manufacturer before charging or converting a system.
Before Buying R449A Refrigerant 10 kg
- Confirm that the equipment is designed or approved for R449A.
- Confirm the required quantity and refrigerant charge.
- Check the equipment manufacturer's documentation.
- Verify the available TDS and SDS.
- Confirm cylinder and packaging requirements.
- Check applicable F-gas and national requirements.
- Ensure that servicing is performed by appropriately trained personnel.
Product Documentation
Professional customers should have access to documentation corresponding to the actual R449A product supplied.
- Safety Data Sheet (SDS)
- Technical Data Sheet (TDS)
- Product label and batch information
- Packaging or cylinder information
- Additional product documentation where applicable
Manufacturer, purity, packaging, cylinder valve, country of origin, certification and other product-specific claims should only be published when supported by the documentation for the actual product being sold.
Wholesale R449A Refrigerant 10 kg
We supply R449A refrigerant 10 kg for professional commercial and industrial refrigeration applications where R449A is specified or approved.
For wholesale enquiries, please contact us with the required quantity, delivery destination and intended application. We can provide information about availability, product documentation and delivery options.
Frequently Asked Questions About R449A
R449A is a zeotropic HFO/HFC refrigerant blend used in commercial and industrial refrigeration systems.
R449A is composed of R32, R125, R134a, R1234yf. The commonly published composition is approximately 24.3%, 24.7%, 25.7%, 25.3% by mass respectively.
R449A has a GWP100 of 1,282 according to the IPCC AR5 methodology.
Yes. R449A has an ozone depletion potential of zero.
R449A is classified as A1 under the referenced ASHRAE refrigerant safety classification.
R449A was developed as a lower-GWP alternative to R404A and has been used in selected retrofit and new-system applications. Compatibility and retrofit requirements must be confirmed for the specific equipment.
R449A can be used as an alternative to R507A in selected compatible refrigeration applications, but the equipment manufacturer's requirements must be checked before conversion.
The 10 kg format is intended for professional refrigeration installation, servicing, maintenance and charging of compatible systems.
Product-specific information should be confirmed using the actual TDS, SDS, product label and accompanying manufacturer or supplier documentation.
Buy R449A Refrigerant 10 kg
Order R449A refrigerant 10 kg for commercial and industrial refrigeration applications where R449A is specified. Contact us for availability, product documentation, wholesale quantities and delivery information.
There are no reviews for this product.
There are no reviews for this product, be the first to leave your review.